Type debug to Turn On Debugging: debug Specify Debugging Destination, screen or file: screen List Functions to Debug - or all - end ends list Names following all will not be debugged - end ends : end Enter NX: 40 Enter NY: 40 Enter NZ: 1 Enter dx: 0.1 Enter dt: 1.0 Enter final time: 2000 Enter intracellular conductivity, (si_x,si_y,si_z): 3 3 0 Enter extracellular conductivity, (se_x,se_y,se_z): 3 3 0 Two ionic models are available FHN (f) 3V-SIM (3) Enter a model (f(dflt),3): f Enter the initial value for v: 0 Enter the Fitzhugh-Nagumo model parameters (alpha): 0.1 Enter the Fitzhugh-Nagumo model parameters (epsilon, gamma): 0.005 0.2 Enter the Fitzhugh-Nagumo model parameters (beta, delta): 1 0 Three problems are available Monodomain (m) 1d Bidomain (1) 2d or 3d Bidomain (b) Enter a problem (m,1,b(dflt)): b Enter the resistance: 1 Enter the surface volume ratio: 2000 Four solution methods are available. Crank_Nicolson (c) Semi_Implicit (i) Split_Dense (s) Split_ADI (t) Enter a method (c,i,s or t): t Choose an initial condition. Plane Wave starting from left (p) Radial wave starting from a corner (c) Radial wave starting from the center (s) Enter the choice (p,c, or s): p Choose a method for stimulation. Cutting half (h) Stimulting the center (c) Enter a method for stimulation (h or c): h Enter the time for the stimulus: 100 Enter the strength of the stimulus: 0.7 Enter the radius of the stimulus: 2