In the simulaton below, the filament was initially placed transmurally (vertically). The scrol wave is inverted to give clockwise scrol wave. The fiber angle is measured from the positive x-axis. Counter clockwise is the positive angle direction. The first angle is the orientation of fiber in the bottom plane and second one is for the top plane.
The domain 15mm x 15mm x 15 mm is discretized into 60 x 60 x 60 unless mentioned otherwise.


MONODOMAIN SIMULATION

(b). With fiber rotation. The last three plots are the xy-, xz-, and yz- projections of the filament in the second plot.

(b1) The angle varies from 60 to -40. Largely remains transmural. (input)
IMAGE IMAGE IMAGE IMAGE IMAGE
(b2). The angle varies from 60 to -60. Largely remains transmural. (input)
IMAGE IMAGE IMAGE IMAGE IMAGE
(b3). The angle varies from 60 to -100. Largely remains transmural. (input)
IMAGE IMAGE IMAGE IMAGE IMAGE
(b4). The angle varies from 60 to -120. Becomes partly intramural. Escapes through bottom plane. (input)
IMAGE IMAGE IMAGE IMAGE IMAGE
(b4). The angle varies from 60 to -120. The initial filament was placed at the center of the domain. It remains transmural this time. (input)
IMAGE IMAGE IMAGE IMAGE IMAGE